Features
Applications
Technical Parameter
Item | Technical Specification | |||||
ISO9060:2018 | Class A | Class B | Class C | |||
ISO9060:1990 | Secondary standard | First class | Second class | |||
Spectral range | 280~3000 nm | 280~3000 nm | 300-3200nm | |||
Output | 0-20mV | 4-20mA,RS485 | 0-20mV | 4-20mA,RS485 | 0-20mV | 4-20mA,0-5V, RS485,SDI-12 |
Supply | / | 12-24VDC | / | 12-24VDC | / | 12-24VDC,5VDC |
Range | 0-4000W/m² | 0-2000W/m² | 0-2000W/m² | |||
Sensitivity | 7-14μV/(W/m²) | 7-14μV/(W/m²) | 7-14μV/(W/m²) | |||
Non-linearity | <±0.5%(100~1000W/m²) | ±1%(100~1000W/m²) | <±3% | |||
Response time | ≤15s(95%) | ≤30s(95%) | ≤60s(95%) | |||
Zero drift( temperature drift:5k/h) | <±2W/m² | <±4W/m² | 2 ±8W/m² | |||
Stability | <±0.8%/year | <±1.5%/year | <±3%/year | |||
Directional response | ±10W/m² | ±20W/m² | ≤±30W/m² | |||
Temperature effect | <2%(-10~40℃) | <4%(-10~40℃) | <8%(-10℃-+40℃) | |||
Operating temperature | -40℃-+80℃ | -40℃-+80℃ | -40℃-+80℃ | |||
Recalibration interval | 2 years | 2 years | 2 years | |||
Calibration basis | ISO9847 | ISO9847 | ISO9847 | |||
Weight(unpacked) | 0.8kg | 0.8kg | 1.2kg | |||
Dimension | 154*101.5mm | 154*101.5mm | ø185*120mm | |||
Transmission module | 4-20mA/RS485:external | 4-20mA: external RS485:built-in | RS485/SDI-12:built-in 4-20mA/0-5V:external | |||
Desiccant | Built-in | Built-in | Built-in | |||
Installation bracket(optional) | Horizontal bracket or adjustable | Horizontal bracket or adjustableBuilt-in | Horizontal bracket or adjustable | |||
Ingress protection | IP67 | IP67 | IP67 | |||
Storage condition | 10℃-60℃@20%-90%RH | 10℃-60℃@20%-90%RH | 10℃-60℃@20%-90%RH |